5
General
Input Frequency 45 - 65 Hz
Noise on Input < 50 milli-Volts
Noise on Output < 50 milli-Volts
Transient Response < 1 V for 50% surge
Efciency > 80 % @ maximum output
Temp. Range -25 to +40 deg. C @ maximum output
Isolation
Input-Output & Input-Case 1500 Vdc
Output-Case 500 VDC (1500Vdc @ 48 V Out)
Isolation Output-Case 500VDC
Length 14.5 in / 36.8 cm
Width 10.2 in / 29.9 cm
Height 5.5 in / 14.0 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Anodized
Fastenings 18-8 Stainless
Weight 12 lb / 5.5 kg
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
* Specications subjects to change without notice.
Installation
MOUNTING
Mount the unit in a DRY location. Allow at least 4 inches of clearance around the heat sink
ns for adequate cooling.
POWER CONNECTION
The unit is supplied with a 5 foot power cable. This should normally be adequate to connect to
a source of power. If you must extend the power cable be sure to use a 3 conductor grounded
type extension cable. For hard wiring to a source of power, cut off the plug, and strip the wires
as necessary. The wire colours are
110 VAC 220 VAC
Brown - AC Hot Brown - AC Hot / Phase 1
Blue - AC Neutral Blue - AC Neutral / Phase 2
Green - Ground Green/Yellow - Ground